Fixed Ultrasonic Flow Meter for Liquids

Original price was: $886.98.Current price is: $88.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
70 People watching this product now!
Description

Favorable price for sale fixed ultrasonic flowmeter, the use of advanced technology can achieve super stability. Suitable for measuring a variety of liquid media, such as water, oil, etc., with a wide range of pipe diameters, supporting DN25mm to 600mm pipe diameter. It supports 10~36VDC/1A power input to ensure low energy consumption operation. Its 5000Hz high-frequency output and RS485 communication interface provide convenience for remote data transmission.

Specification

Model T-SUP-1158S
Measurement Accuracy 0.01~5.0m/s (0.03~16ft/s)
Accuracy Class Grade 1
Pipe Diameter Range 25mm~600mm (1° ~24* )
Measuring Medium Water, oil and other single medium liquid
Pipe Material Carbon steel, stainless steel, PVC
Output OCT pulse output: 0-5000Hz
Analog Output 4~20mA, maximum load resistance 7500
Communication Interface RS485 communication interface supports MODBUS protocol
Power Supply 10~36VDC/1A
Transmitter Installation Environment Temperature -10℃ ~ 50℃
Special Sensor Measurement Medium Temperature 0℃~ 80℃
Transmitter Material PC / ABS plastic housing
Protection Class IP65
Sensor Material Sealed design, protection class IP68
Standard Cable Length 9m (30ft)
Transmitter Weight 0.7kg
Sensor Weight 0.4kg


Fixed Ultrasonic Flow Meter Transducer Selection

Transducer Measuring Pipe Size Range Temperature Range Dimensions (mm)
Standard clamp-on transducer – Small DN32-DN100 -40℃~90℃ 45*25*32
Standard clamp-on transducer – Medium DN50-DN700 64*39*44
Standard clamp-on transducer – Large DN300-DN6000 97*54*33
High-temp clamp-on transducer – Small DN32-DN100 -30℃~160℃ 45*25*32
High-temp clamp-on transducer – Medium DN50-DN700 64*39*44
High-temp clamp-on transducer – Large DN300-DN6000 97*54*33


Fixed Ultrasonic Flow Meter Transducer Installation

1. Choosing right installation position

  • When installing the transducer, the piping must have a straight section of sufficient length, the longer the better. It is generally recommended that the length of the straight section of pipe upstream is 10 times the diameter of the pipe, downstream is 5 times the diameter of the pipe, and the length from the pump port should be 30 times the diameter of the pipe. At the same time, make sure that the liquid in the section of pipe is in a full state to ensure the accuracy of the measurement.
  • Ensure that the temperature of the pipe being measured is within the operating range of the sensor, which should normally be in a room temperature environment. The corrosion and scaling of the pipe also needs to be considered. Ideally, it is recommended that a newer pipe be selected for measurement. If deteriorated pipe must be used, the pipe wall thickness should be reduced to account for the degree of corrosion, or scaling should be treated as if the pipe were lined.

2. Transducer installation method

  • Z-type installation: Generally applicable to pipes with a diameter greater than DN100mm.
  • V-type installation: Generally applicable to pipes of DN20-300mm.
  • W-type installation: Generally applicable to pipes of DN10-100mm.

ATTENTION: * The installation distance is shown after entering the pipe parameters into the ultrasonic flow meter.

Fixed Ultrasonic Flow Meter Applications

Tips: Can fixed ultrasonic flow meters be used for high or low temperature fluids?

Yes, fixed ultrasonic flowmeter can be used for high or low temperature fluid measurement. Different models of ultrasonic flowmeter have their own temperature operating range, usually the standard model can be in -30℃ to 160℃ range of work. If you need to measure the extreme temperature of the fluid, such as higher than 160℃ or lower than -30℃ liquid or gas, it is recommended to choose a special model with a high-temperature or low-temperature sensor to ensure the accuracy of the measurement and the service life of the equipment.