Fixed Hydrogen Cyanide (HCN) Gas Monitor, 0 to 10/50/100 ppm

Price range: $112.99 through $162.99

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
74 People watching this product now!
Description

Cost-effective hydrocyanic acid (HCN) gas monitor with a wide range of detection, 0 to 10/20/50/100 ppm multi-speed detection range, able to accurately monitor harmful gases in the environment. The compact design makes it easy to carry and suitable for many occasions. Optional 4-20mA and RS485 signals are available, as well as relay output function. With the purchase of this hydrogen cyanide detector, you get a professional gas detection tool at a great price, ensuring a safe working environment.

Specification

Model GD300-HCN
Detected Gas Hydrogen Cyanide (HCN)
Measure Range 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm
Resolution 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm)
Install Method Wall-mounted, piping type, flow-type
Output Signal (Optional) 1. 4-20mA and RS485, 2. Relay outputone group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
Precision ≤±3%F.S. (higher precision is available)
Zero Shift ≤±1%(F.S./year)
Display 4 digits Nixie tube display
Power Connection Type G1/2 is the inlet and outlet for power and signal lines; Pipe-mounted typeThe installation thread size of the instrument is M45*P2.0
Pipe-mounted Type M45*P2.0
Thread Size M45*2mm
Temperature -20℃ ~ 50℃
Humidity 0-95%RH (non-condensing)
Explosion-Proof Ex dⅡCT6
Degree of Protection IP65
Alarm Mode Sound, light
Material CaseDie-cast aluminum, Sensor housingaluminum alloy or 316 stainless steel
Power 12-36V DC
Dimensions 180×150×90mm
Weight 1.6kg
Approval CE, ATEX
Power Adapter Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, UK plug)
Warranty 12 months


Fixed Gas Monitor User Manual

  • Fixed Gas Monitor User Manual.pdf
  • Protocol of RS485 for Fixed Gas Monitor.pdf
  • Calibration Procedures of Fixed Type Gas Monitor.pdf

Gas Monitor Functions

  • This hydrogen sulfide gas detector adopts three-wire 4-20mA analog signal output, relay output, RS485 output (optional).
  • The original imported sensors, with a unique infrared remote control function, non-contact operation and maintenance of hydrogen gas tester.
  • Compatible with a variety of control alarms, PLC, DCS and other control systems, you can realize remote monitoring, gas monitoring is more accurate and reliable.
  • Explosion-proof design grade is ExdlCT6, fast, credible and more stable.
  • Full software auto-calibration function with temperature compensation can perfectly realize the compensation of gas concentration under different temperature environment.

Fixed HCN Gas Monitor Details

 

Fixed Hydrogen Cyanide Gas Monitor with Alarm Dimension (Unit: mm)

Tips: What is hydrogen cyanide?

Hydrogen cyanide (HCN) is a colorless, toxic chemical, usually in the form of a gas with a bitter almond odor. It is used in a wide range of industrial applications, such as in the manufacture of plastics, fertilizers and chemicals. At the same time, hydrogen cyanide is a highly hazardous substance, fatally toxic to humans and animals in high concentrations, and is often used in pesticides or chemical weapons. Because of its hazardous nature, the production, storage and transportation of hydrogen cyanide are subject to strict regulations and safety controls.

Additional information
Measuring Range *

,

,

,

Signal Output *

,

Relay Output *

,