Portable Nitrogen Dioxide (NO2) Gas Tester, 0 to 100/500/1000 ppm

Price range: $72.99 through $288.37

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
73 People watching this product now!
Description

High quality portable nitrogen dioxide (NO2) gas detector, range selectable from 0 to 20/50/100/500/1000 ppm, adopts electrochemical detection principle, response time less than 10 seconds, accuracy ≤±3% F.S.. The gas detector supports USB high-speed data transmission and logging, built-in ten-stage adjustable pump suction, flow rate up to 1L/min, equipped with sound and light vibration alarm, suitable for a variety of industrial scenarios.

Specification

Model GD200-NO2
Sampling Method Pumping suction, flow rate can be up to 1L/min, ten grades of pumping suction for selection.
Detection Principle Electrochemistry
Gas Nitrogen Dioxide (NO2)
Range (Optional) 0 to 20 ppm, 0 to 50 ppm, 0 to 100 ppm, 0 to 500 ppm, 0 to 1000 ppm
Resolution 0.01ppm (0-20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-500/1000ppm)
Accuracy ≤±3% F.S.
Responce Time ≤10s
Repeatability ≤±1%
Recovery Time ≤10s
Linearity Error ≤±1%
Zero Shift ≤±1% (F.S./year)
Data Logging (Optional Function) High speed data transmission by USB, available for data downloading and printing
Alarms Sound, light and vibration
Display LCD dot matrix display
Language Chinese/English
Battery 3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time 100h (Pump off)
Explosion-proof Grade Ex ia llC T4
Protection Grade IP66
Certification CE, ATEX
Operating Temperature -20℃~50℃
Operating Humidity 0~95%RH (non-condensing)
Operating Pressure 0.8~1.2bar
Dimension 205*75*32mm
Weight 300g
Warranty 12 months
Extension Probe About 480mm (Total Length), About 300mm (Probe Head)


Portable Gas Monitor User Manual

  • Tool Gas Monitor User Manual.pdf
  • Tool Gas Monitor Data Downloading Operation Instruction.pdf

Communication Protocol

  • Tool Handheld Gas Monitor Communication Protocol V1.0.pdf

Portable Gas Monitor Calibration Accessories – Gas Pressure Regulator

  • Tool Single Stage Pressure Regulator User Manual

Gas Detector Software

  • Tool Portable Gas Monitor DataExport Software

Portable NO2 Gas Tester Features

  • Original imported high-precision sensors to ensure the accuracy and reliability of the test results.
  • Fast data transfer via USB interface with optional download and print functions.
  • Multi-functional display interface with optional display of gas type, concentration, maximum value, local time and ambient temperature.
  • Operation interface with multi-language support, easy switching and friendly user experience.
  • Built-in miniature sampling pump, suction power can be adjusted in ten gears, and with explosion-proof qualified certification, excellent safety performance.

Gas Tester Functions

  • Real-time monitoring of gas concentration in the environment or confined space, with automatic alarm for exceeding the standard.
  • Built-in self-calibration function and zero calibration function ensure accurate and reliable monitoring.
  • One key to restore the factory settings, to avoid the trouble caused by misoperation.
  • Equipped with temperature and pressure compensation function, adapting to gas monitoring under different environmental conditions.
  • Dual-stage sound and light alarm system, alarm point can be customized, flexible response to various situations.
  • Built-in high-capacity lithium polymer rechargeable battery, providing long life.
  • Adopt pump suction sampling mode, adjustable suction force to ensure accurate sampling.
  • Made of special engineering plastics with anti-slip, waterproof, dustproof and explosion-proof features.

Portable Nitrogen Dioxide Gas Tester Details

 

Applications

Tips: How do I use a nitrogen dioxide gas tester to detect a leak of nitrogen dioxide gas?

To detect a NO2 gas leak, first make sure the tester is properly calibrated and charged. Then, place the gas detector close to an area where there may be a leak, such as a pipe fitting, valve, or gas storage tank. Start the unit and observe the NO2 concentration reading on the display. If the reading is outside the normal range or reaches the preset alarm value, there is a NO2 leak and immediate safety measures need to be taken.

Additional information
Measuring Range *

,

,

,

,

Charger Plug *

,

,

,

Extension Probe *

,