1-600mm Ultrasonic Thickness Gauge

Price range: $110.99 through $270.70

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
26 People watching this product now!
Description

Competitive price ultrasonic thickness tester. 0.01mm resolution, 1000-9999m/s sound speed range, 2000 groups data storage, can do continuous or single measurement. Measuring tool used to monitor various pipelines and pressure vessels in production equipment, monitor their thinning degree after being corroded during use.

Specification

Model T-BT180C
Measuring Range 1-600mm (Standard)
Accuracy

Thickness <10mm: ±0.04mm

Thickness >10mm: ±0.5%H+0.01mm (H represents the actual thickness of the measured object)

Resolution 0.01mm
Sound Speed Range 1000-9999 m/s
Measurement Mode Continuous Measurement & Single Measurement
Calibration 4mm (Steel)
Data Storage 2000 Groups
Units Metric & Imperial
Connect to Computer √
Shutdown Mode Manual and Automatic
Power Supply AA Battery
Dimension 170*80*38mm
Package Included

1*1-600mm Ultrasonic Thickness Gauge

1*Standard Probe (8/ 10mm)

1*Coupling Agent

2*AA Batteries

1*Packing Box

1*Instruction Book

1*Appraisal Certificate

1*Certificate of Conformity

1*Warranty Card

Details

Applications

Selectable probes

Picture Type Model Frequency (MHZ) Probe Diameter Measuring Range Surface Temperature of the Measured Object Feature
Standard Probe N05 5 8/ 10mm 1-600mm (Steel) -10~60℃ Use at room temperature
Coarse Crystal Probe N02 2 12mm

3-300mm (Steel)

5-40mm (Cast Iron)

-10~60℃ Used to measure crystalline materials such as cast iron

Micro Diameter Probe N07 7 4mm/ 6mm 0.65mm-260mm (Steel) -10~60℃ Used to measure thin walls and small arcs
High Temperature Probe HT5 5 14mm 3-200mm (Steel) -10~400℃ Used to measure materials whose temperature is lower than 350℃

Tips: Factors affecting the accuracy of ultrasonic thickness gauges

  • The effect of sound speed. For occasions where the requirements for measurement results are not high, the speed of sound found from various data can be used for measurement, but the speed of sound found from various data is often significantly different from the actual sound speed of the material. The accurate measurement method is to take a standard sample that is exactly the same as the material to be tested. The standard sample is required to be flat and smooth, and the same thickness as the maximum thickness of the tested sample to determine the sound velocity of the material.
  • Probe selection. In general, the sound velocity in solid material decreases with the increase of temperature, so the special probe for high temperature sample should be used. When ultrasonic wave passes through the casting and austenitic steel, the scattering attenuation will be serious due to the uneven structure or the bulky grain, which may make the echo obliteration, resulting in no display. Therefore, it is recommended to choose the coarse crystal special probe with lower frequency (2.5 MHz). The radius of curvature of the workpiece is too small, especially when measuring the thickness of small-diameter tube. Since the surface of the probe is usually flat and the contact with the surface is point contact or line contact, the transmission of sound intensity is low (the coupling is not good), the special probe with small diameter can be selected (6mm).
  • Ultrasonic thickness gauge calibration. Both the probe and the circuit have a certain signal transmission time, which must be subtracted from the total transmission time. This process is called instrument calibration. Ignoring this step will cause a large error in the measurement result. During calibration, press the calibration key of the ultrasonic thickness gauge, apply a little couplant to the probe and lightly press it on the calibration test block that comes with the instrument. When the instrument displays the thickness value of the standard test block indicated in the manual, the calibration is completed. After replacing the battery and probe of the ultrasonic thickness gauge, and before each measurement, it should be calibrated.