Handheld Dew Point Meter for Temp & Humidity Testing

Original price was: $398.82.Current price is: $119.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
68 People watching this product now!
Description

Designed for precise HVAC, cleanroom, and manufacturing audits, this handheld dew point meter operates from -30℃ to 80℃ with ±0.1℃ accuracy. Equipped with interchangeable probes and a clear electronic screen, it ensures flexible, real-time quality control in the field. Plus, built-in data logging automatically exports up to 99 datasets directly into spreadsheets, streamlining your environmental compliance and long-term facility monitoring.


Specification

Model T-HG970
Environment temperature
Measurement Range -30~80℃ (-22~176°F)
Accuracy ±0.1 ℃
Resolution 0.01 ℃/°F
Sampling Frequency 1 time per second
Dew point temperature
Dew point temperature range -30 ~ 80 ℃
(See the “Dew Point Accuracy Table” for details on accuracy)
Relative Humidity
Measurement Range 0~100%RH
Accuracy ±1.5%RH(0%RH~80%RH,25℃)
Resolution 0.1%RH
Response Time Less 10S (90% 25℃,wind speed 1m/s)
Wet Bulb Temperature 
Wet Bulb Temperature Range -20 ~ 60 ℃
Other
Records 32000 records (Recorder function)
Store-in 99 groups (Special data can be manually saved on demand, additional saving, directly read on the display)
Power A standard 9V 6LR61 or 6F22 battery
Battery Life About 300 hours(use 6LR61 9V alkaline battery)
Operating Environment 0 ~ 40℃ (32 ~ 104°F), < 80% RH Non – Condensing
Storage environment -10~ 60℃ (14 ~ 140°F), <80% RH Non – Condensing
Weight and Size About 200g(Battery included not including the probe),215mm*58mm*33mm
Probe Rod Length Stainless steel powder sintering protective cover
Stainless steel grid protective cover

Features

  • Easy Maintenance & Probe Replacement: Supports software self-calibration and standalone probe swap to cut long-term maintenance costs.
  • 32,000 Data Logging & Quick Retrieval: Stores up to 32,000 readings with rapid access to 99 key datasets for fast on-site verification.
  • Ultra-Portable with Backlit Display: A lightweight 200g body powered by a 9V battery, featuring a clear backlit screen for any lighting condition.
  • Multi-Format Data Export: Direct USB connection automatically generates spreadsheets and exports in PDF, XLS, and CSV formats.
  • Versatile & Practical Functions: Features ℃/℉ switching, Max/Min/Hold locking, data management, and Auto Power-Off. 


Details


Applications

This handheld dew point meter is not only suitable for pharmaceutical manufacturing, indoor air Quality, industrial equipment maintenance and wine cellar storage, but can also be applied to any temperature, humidity, and dew point testing that falls within its measurement range.

FAQs

Q: Can I see temperature, humidity, and dew point all at once on the screen during field checks?

A: Yes, the electronic screen displays all three parameters simultaneously. Temperature, relative humidity, and dew point update in real time on a single view, so you don’t need to manually switch between menus while on-site.

Q: Is the built-in memory for 99 datasets enough, and what happens when it gets full?

A: 99 slots are plenty for standard inspection rounds. When you hit the limit, simply connect the unit to generate and export your spreadsheets to a computer. Once your files are backed up, clear the memory on the device to free up space for your next run.

Q: Why does the new probe feel loose or refuse to tighten properly when I try to install it?

A: That usually happens if the module isn’t pushed in far enough. Make sure to align the pins and turn the nut counterclockwise two or three times to engage the threads, then press the probe shaft firmly inward toward the main body until it seats properly before tightening the nut all the way.

Q: Why should I swap out the battery immediately as soon as the low-battery icon shows up? 

A: A weak battery can cause voltage drops that compromise sensor accuracy and stability. Swapping in a fresh 9V battery as soon as the warning appears ensures your readings remain precise-just remember to latch the cover securely afterward.

Q: Can I use isopropyl alcohol or heavy-duty cleaners if the housing gets greasy in the field?

A: Avoid alcohol, harsh solvents, or abrasive chemicals, as they can degrade the protective housing. Stick to a soft cloth lightly dampened with mild soapy water to clean the body, then wipe it dry.